![]() The PowerView hub responds to a NetBios Name Service name query for a PBDU-Hub3.0 type NB (0x20) class IN (0x1), but seemingly only when the transaction ID is 0x3e8. For example, in GET the SHADE_ID is the variable field that would be filled in with a shade ID number. This document uses UPPERCASE letters in URLs to indicate a variable field. Consult your router's manual for instructions.Īll API request and response data uses the application/json content type. Setting a static IP for your hub is beyond the scope of this document. If you haven't done this you can swap powerview for the IP address of your hub. This document assumes your have given your hub a static IP address and a hostname of powerview. ![]() The PowerView Hub API is accessible via HTTP. If the shade slider within the Control4 GUI doesn’t closely reflect the physical position of the shade while it is in motion, adjust the ‘Travel Time’ property in composer to more accurately match the amount of time (in seconds) it takes the shade to physically travel from open to close.This document describes the Hunter Douglas PowerView API connecting to the PowerView Hub on the local network. It is likely the movement chosen does NOT match the physical movement of the shade. If the shade opens/closes opposite of the commands sent in Control4, check the ‘Blind Type’ and ‘Blind Movement’ for the “Crestron Shade” in System Design. Serial driver MUST be configured for 9600 Baud, 8 Data Bits, 1 Stop bit, No Parity Either switch to a null modem cable or enable the null modem settings in ComposerĢ) If there is communication received from Control4 however it is garbled, check your RS-232 settings in the 2-way RS-232 module. To troubleshoot RS-232 issues, use Crestron debugger to view signals to and from the 2-way RS-232 module.ġ) If there is no communication received from Control4, check your null modem settings. Most issues that arise are due to improperly configured RS-232 connections. Use if it is determined the Crestron processor or Control4 controller has stopped responding to commands. Kill All Timers: Forces all timers within the driver to expire. Poll Shade Level: Updates the current status within the Control4 GUI of the shade. Poll All Shades: Updates the current status within the Control4 GUI of all shades connected to the driver.Ĭlear Incoming Buffer: Clears all incoming commands from the Crestron processor. Open All Shades: Opens all shades connected to the driver.Ĭlose All Shades: Closes all shades connected to the driver. Note: This setting is to ensure the slider within the Control4 GUI corresponds to the current physical position of the shade while it is in motion. Travel Time: Enter Time (in seconds) it takes the shade to physically travel from open to close. Debug mode will revert to “off” after a predetermined time. Properties (Crestron Shade):ĭebug Mode: Select a mode to debug the driver. ![]() If it is determined that some commands are ‘missed/ignored’ by the Crestron processor, adjust the command delay to speed up or slow down transmitted commands.ĭebug Mode: Select a mode to debug the driver. License Key: Input the license key from your Blackwire Designs dealer account and press the “set” button to activate the driver.ĭirector MAC: Displays the MAC of the Control4 processor running Director.Ĭommand Delay: Displays the delay (in milliseconds) that Control4 will delay transmitting consecutive RS-232 commands to the Crestron processor. License Status: Displays the current license status of the driver according to Blackwire Designs licensing server.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |